<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DMS Ltd &#187; European Directive 2004/22/EC</title>
	<atom:link href="http://www.dmsltd.com/blog/tag/european-directive-200422ec/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.dmsltd.com/blog</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Fri, 12 Aug 2011 09:55:01 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Measuring Instruments Directive</title>
		<link>http://www.dmsltd.com/blog/2010/07/measuring-instruments-directive/</link>
		<comments>http://www.dmsltd.com/blog/2010/07/measuring-instruments-directive/#comments</comments>
		<pubDate>Thu, 01 Jul 2010 14:44:58 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Electric Meters]]></category>
		<category><![CDATA[Utility Metering Regulation]]></category>
		<category><![CDATA[Water Meters]]></category>
		<category><![CDATA[European Directive 2004/22/EC]]></category>
		<category><![CDATA[European Regulation]]></category>
		<category><![CDATA[Measuring Instruments Directive]]></category>
		<category><![CDATA[metering performance]]></category>
		<category><![CDATA[NF EN14154]]></category>
		<category><![CDATA[overload flowrate]]></category>
		<category><![CDATA[transition flowrate]]></category>
		<category><![CDATA[water meter measurement techniques]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=323</guid>
		<description><![CDATA[New European Regulation for Water Meters
European Directive 2004/22/EC is aimed at harmonising the regulations and classifications in the area of water metering across Europe. With effect from 30th October 2006 it replaces all European directives and national regulations making it necessary for all water meters to meet the standard of NF EN14154 and/or recommendation OIML [...]]]></description>
			<content:encoded><![CDATA[<h2>New European Regulation for Water Meters</h2>
<p>European Directive 2004/22/EC is aimed at harmonising the regulations and classifications in the area of <a title="Water metering products" href="http://www.dmsltd.com/Water_Meters_-_Hot_and_Cold" target="_self">water metering</a> across Europe. With effect from 30th October 2006 it replaces all European directives and national regulations making it necessary for all water meters to meet the standard of NF EN14154 and/or recommendation <a title="OIML R49" href="http://www.nmo.bis.gov.uk/content.aspx?sc_id=337" target="_blank">OIML R49</a>.</p>
<p><span id="more-323"></span></p>
<p>So what does this mean in practice? Well it changes the baseline that is used to define the metering performance of a water meter.</p>
<div style="margin-top: 10px;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/07/comparing_techniques.jpg"><img class="size-full wp-image-335 alignright" title="comparing_techniques" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/07/comparing_techniques.jpg" alt="comparing water meter measurement techniques" width="424" height="241" /></a></div>
<p>A water meter is now defined by:</p>
<ul>
<li>Q3 : Continuous flowrate</li>
<li>R : Q3/Q1 ratio (where Q1 is the flowrate)</li>
</ul>
<p style="margin-top: 10px;">Secondary characteristics are:</p>
<ul>
<li>Q2 : The transition flowrate given by Q2/Q1</li>
<li>Q4 : The overload flowrate given by Q4/Q3</li>
</ul>
<p style="margin-top: 10px;">This means that the possible values of Q3 (measured in cubic metres) and R are:</p>
<table border="1">
<tbody>
<tr>
<td width="50" align="center"><strong>Q3</strong></td>
<td width="50" align="center"><strong>R</strong></td>
</tr>
<tr>
<td width="50" align="right">1.0</td>
<td align="right">10.0</td>
</tr>
<tr>
<td width="50" align="right">1.6</td>
<td align="right">12.5</td>
</tr>
<tr>
<td align="right">2.5</td>
<td align="right">16.0</td>
</tr>
<tr>
<td align="right">4.0</td>
<td align="right">20.0</td>
</tr>
<tr>
<td align="right">6.3</td>
<td align="right">25.0</td>
</tr>
<tr>
<td align="right">10.0</td>
<td align="right">31.5</td>
</tr>
<tr>
<td align="right">16.0</td>
<td align="right">40.0</td>
</tr>
<tr>
<td align="right">25.0</td>
<td align="right">50.0</td>
</tr>
<tr>
<td align="right">40.0</td>
<td align="right">63.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">80.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">100.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">125.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">160.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">200.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">250.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">315.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">400.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">500.0</td>
</tr>
<tr>
<td align="right"></td>
<td align="right">630.0</td>
</tr>
</tbody>
</table>
<div style="margin-top: -360px;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/07/water_meter_flowrate_example1.jpg"><img class="alignright size-full wp-image-381" title="water_meter_flowrate_example" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/07/water_meter_flowrate_example1.jpg" alt="water meter flowrate calculation example" width="593" height="422" /></a></div>
<div id="_mcePaste" style="position: absolute; left: -10000px; top: 703px; width: 1px; height: 1px; overflow: hidden;">&lt;div&gt;<br />
&lt;h2&gt;Model Approval&lt;/h2&gt;<br />
Model approval has been replaced by the &lt;strong&gt;EC type examination certificate&lt;/strong&gt; which reinforces the requirements in terms of test benches and methods.&lt;/div&gt;</div>
<div style="margin-top:420px">
<h2>Model Approval</h2>
<p>Model approval has been replaced by the <strong>EC type examination certificate</strong> which reinforces the requirements in terms of test benches and methods.</div>
<h2>Can you still buy and fit class A, B &#038; C water meters?</h2>
<p>Yes for 10 years at the most as products approved before the MID (Oct 2006) were approved for a 10 year period.</p>