<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DMS Ltd &#187; Non Invasive Flow Meter</title>
	<atom:link href="http://www.dmsltd.com/blog/tag/non-invasive-flow-meter/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.dmsltd.com/blog</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Fri, 12 Aug 2011 09:55:01 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>DMS Dynamic Non Invasive Clamp On Flow Meter</title>
		<link>http://www.dmsltd.com/blog/2009/12/dms-dynamic-non-invasive-flow-meter/</link>
		<comments>http://www.dmsltd.com/blog/2009/12/dms-dynamic-non-invasive-flow-meter/#comments</comments>
		<pubDate>Wed, 09 Dec 2009 16:40:33 +0000</pubDate>
		<dc:creator>chrisbishop</dc:creator>
				<category><![CDATA[Non Invasive Flow Meters]]></category>
		<category><![CDATA[Clamp On Flow Meter]]></category>
		<category><![CDATA[DMS Dynamic Non Invasive Flow Meter]]></category>
		<category><![CDATA[Flow Meters]]></category>
		<category><![CDATA[Non Invasive Flow Meter]]></category>
		<category><![CDATA[Water Meters]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=11</guid>
		<description><![CDATA[NEW!! DMS Dynamic ultrasonic flow meter / energy meter clamp-on to the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. DMS Dynamic is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><strong> </strong></p>
<p style="text-align: center;"><img class="size-full wp-image-18 aligncenter" title="DMS Dynamic 2009" src="http://www.dmsltd.com/blog/wp-content/uploads/2009/12/DMS-Dynamic-2009.jpg" alt="DMS Dynamic 2009" width="350" height="149" /></p>
<p><span id="more-11"></span></p>
<p>NEW!! <strong><span style="text-decoration: underline;">DMS Dynamic</span></strong> ultrasonic flow meter / energy meter clamp-on to the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. DMS Dynamic is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.</p>
<p><a href="http://www.dmsltd.com/DMS_Dynamic_Non_Invasive_Meters" target="_blank"><img class="alignnone size-thumbnail wp-image-21" title="Click Here" src="http://www.dmsltd.com/blog/wp-content/uploads/2009/12/Click-Here-150x150.jpg" alt="Click Here" width="56" height="33" />To See The DMS Dynamic Section For More Info</a></p>
<p>The DMS Dynamic is available in two versions: a stand-alone flow meter, and an energy flow meter used in conjunction with a Supercal 531 Heat Integrator. The energy flow meter measures energy usage in kWh or MWh and is ideal for retrofit, chilled water and other HVAC applications.</p>
<p><strong><span style="text-decoration: underline;">FEATURES</span></strong></p>
<ul>
<li>May be used to measure clean liquids as well as those with small amounts of suspended solids or aeration (e.g., surface water, sewage).</li>
<li>Bi-directional flow measurement system. Totalizer options include forward, reverse and net total.</li>
<li><span style="color: #ff0000;">Modbus RTU over RS485 communications </span></li>
<li><span style="color: #ff0000;"><span style="color: #0000ff;">Ethernet connection includes BACNet®/IP</span> </span></li>
<li><span style="color: #008000;">Ethernet/IPTM and Modbus TCP/IP protocols.</span></li>
<li>Compact enclosure uses large, easy-to-read digital display.</li>
<li>Rugged, aluminum enclosure ensures a long service life in harsh environments.</li>
</ul>
<p><strong><span style="text-decoration: underline;">BENEFITS</span></strong></p>
<ul>
<li>Reduced material costs: clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers, and filters.</li>
<li>Reduced installation time: the DMS Dynamic may be installed and fully operational within minutes.</li>
<li>Reduced maintenance costs: with no moving parts, there is nothing on the DMS Dynamic to wear down – no repair kits or replacement parts are needed.</li>
<li>No need to shut down the process for installation or maintenance due to clamp-on sensor design.</li>
</ul>