<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DMS Ltd</title>
	<atom:link href="http://www.dmsltd.com/blog/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.dmsltd.com/blog</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Fri, 12 Aug 2011 09:55:01 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Kamstrup Renewable Heat Incentive (RHI) Scheme</title>
		<link>http://www.dmsltd.com/blog/2011/05/kamstrup-renewable-heat-incentive-rhi-scheme/</link>
		<comments>http://www.dmsltd.com/blog/2011/05/kamstrup-renewable-heat-incentive-rhi-scheme/#comments</comments>
		<pubDate>Tue, 31 May 2011 09:00:55 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Electric Meters]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=726</guid>
		<description><![CDATA[The Government will allow those who wish to make a claim against the Renewable Heat Incentive Scheme to choose any heat meter that meets the Class 2 requirements listed in Annex MI-004 of the EU Measuring Instruments Directive (MID) 2004.

The following Heat Meters supplied by DMS, comply to these requirements.


The Kamstrup Ultraflow is an ultrasonic [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: left;">The Government will allow those who wish to make a claim against the <a title="Renewable Heat Incentive Scheme" href="http://www.decc.gov.uk/en/content/cms/what_we_do/uk_supply/energy_mix/renewable/policy/incentive/incentive.aspx " target="_blank">Renewable Heat Incentive Scheme</a> to choose any heat meter that meets the Class 2 requirements listed in Annex MI-004 of the EU Measuring Instruments Directive (MID) 2004.</p>
<p><span id="more-726"></span></p>
<p style="text-align: center;"><strong>The following Heat Meters supplied by DMS, comply to these requirements.</strong></p>
<p></br><br />
<a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/KAMS1.bmp"><img class="alignleft size-full wp-image-758" title="KAMS" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/KAMS1.bmp" alt="" width="170" height="135" /></a></p>
<p>The Kamstrup <strong>Ultraflow</strong> is an ultrasonic &#8217;static&#8217; meter with no moving parts</p>
<p><strong>Multical</strong> 601 Power Options: 240Vac, Lithium Battery</p>
<p>Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p>Sizes Avaliable: 1/2&#8243; (qp0.6) &amp; Cooling (65-T) <strong>Not</strong> Suitable for Glycol content</p>
<p>Communication Modules: Pulse, M-bus, Analogue, Radio and LON<br />
<br clear="all" /></p>
<p style="text-align: left;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/402_GB_kWh_22.jpg"><img class="alignleft size-thumbnail wp-image-759" title="402_GB_kWh_2" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/402_GB_kWh_22-150x150.jpg" alt="" width="150" height="150" /></a></p>
<div style="margin-left:180px;">
<p style="text-align: left;">The Kamstrup <strong>Multical 402</strong> is an ultrasonic &#8217;static&#8217; compact meter with no moving parts</p>
<p style="text-align: left;"><strong>Multical 402</strong> Power Options: 240Vac, 24Vac, Lithium Battery</p>
<p style="text-align: left;">Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p style="text-align: left;">Sizes Avaliable: 1/2&#8243; (qp0.6) to 3/4&#8243; (qp2.5)</p>
<p style="text-align: left;">Suitable for: Heating (402W) &amp; Cooling (402T Not suitable for Glycol content)</p>
<p style="text-align: left;">Communication Modules: Pulse, M-bus and Radio</p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2011/05/kamstrup-renewable-heat-incentive-rhi-scheme/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Renewable Heat Incentive (RHI) Scheme</title>
		<link>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/</link>
		<comments>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/#comments</comments>
		<pubDate>Tue, 31 May 2011 09:00:36 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Cooling Meters]]></category>
		<category><![CDATA[Glycol Meters]]></category>
		<category><![CDATA[Sontex Heat Meters]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=707</guid>
		<description><![CDATA[The Government will allow those who wish to make a claim against the Renewable Heat Incentive Scheme to choose any heat meter that meets the Class 2 requirements listed in Annex MI-004 of the EU Measuring Instruments Directive (MID) 2004.
The following Heat Meters supplied by DMS, comply to these requirements.

 

The Sontex Superstatic 440 is [...]]]></description>
			<content:encoded><![CDATA[<p>The Government will allow those who wish to make a claim against the <a title="Renewable Heat Incentive Scheme" href="http://www.decc.gov.uk/en/content/cms/what_we_do/uk_supply/energy_mix/renewable/policy/incentive/incentive.aspx " target="_blank">Renewable Heat Incentive Scheme</a> to choose any heat meter that meets the Class 2 requirements listed in <em>Annex </em>MI-004 of the EU Measuring Instruments Directive (MID) 2004.<span id="more-707"></span></p>
<p style="text-align: center;"><strong>The following Heat Meters supplied by DMS, comply to these requirements.<br />
</strong></p>
<p><strong> </strong></p>
<p><strong><a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms-blog1.jpg"><img class="alignleft size-full wp-image-709" title="dms blog" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms-blog1.jpg" alt="" width="176" height="150" /></a></strong><br />
The Sontex <strong>Superstatic 440</strong> is a &#8217;static&#8217; meter with no moving parts<br />
using the fluid oscillation principle</p>
<p><strong>Supercal 531</strong> Power Options: 240Vac, 24Vac, 24VDC, Lithium Battery</p>
<p>Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p>Sizes Available: 1/2&#8243; (qp1.00) to DN500 (qp1500)</p>
<p>Suitable for: Heating &amp; Cooling with Glycol content</p>
<p>Communication Modules: Pulse (volt free,) M-bus, RS232, Analogue, Radio</p>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms.jpg"><img class="size-full wp-image-711 alignleft" title="dms" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms.jpg" alt="" width="170" height="136" /></a><br />
The Sontex <strong>Superstatic 449</strong> is a &#8217;static&#8217; Compact Meter with no moving parts<br />
using the fluid oscillation principle</p>
<p>Supercal 531 Power Options: 240Vac, 24Vac, 24VDC, Lithium Battery</p>
<p>Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p>Sizes Available: 1/2&#8243; (qp1.0) to 3/4&#8243; (qp2.5)</p>
<p style="text-align: left;">Suitable for: Heating &amp; Cooling with Glycol content (released 2012)</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Superstatic 449 Compact Heat Meter from Sontex</title>
		<link>http://www.dmsltd.com/blog/2011/04/new-superstatic-449-compact-heat-meter-from-sontex/</link>
		<comments>http://www.dmsltd.com/blog/2011/04/new-superstatic-449-compact-heat-meter-from-sontex/#comments</comments>
		<pubDate>Tue, 19 Apr 2011 13:56:09 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Sontex Heat Meters]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=701</guid>
		<description><![CDATA[﻿
New Superstatic 449 Compact Heat Meter from Sontex

The Superstatic fluid oscillator measuring principle, used with the heat meters from Sontex, guarantees a high measuring accuracy and measuring durability. This fact was proved with top marks during the last heat meter tests of the German District Heating Association.
Now Sontex presents as a world innovation the small [...]]]></description>
			<content:encoded><![CDATA[<p>﻿<a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/04/sontex1.jpg"><img class="alignnone size-full wp-image-702" title="sontex" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/04/sontex1.jpg" alt="" width="345" height="84" /></a><br />
New Superstatic 449 Compact Heat Meter from Sontex</p>
<p><span id="more-701"></span></p>
<p>The Superstatic fluid oscillator measuring principle, used with the heat meters from Sontex, guarantees a high measuring accuracy and measuring durability. This fact was proved with top marks during the last heat meter tests of the German District Heating Association.</p>
<p>Now Sontex presents as a world innovation the small fluid oscillator heat meter Superstatic 449, an innovation with all known advantages of a Superstatic heat meter. The Superstatic 449 is a compact heat meter with MID homologation according to EN 1434 class 2 that perfectly complements the existing mechanical compact heat meter Supercal 539 (qp 0,6 &#8211; 2,5) and the static heat meter Superstatic 440 (qp 1 – 1500) at small flows.</p>
<p>The Superstatic 449 is offered for flows of qp 0,6 – 2,5 and can also be used as a cooling meter thanks to the waterproof design. The small fluid oscillator works without restriction in all mounting positions<br />
horizontal, riser or downward flows. The Superstatic 449 can easily be integrated in existing or new heating or cooling installations thanks to the comprehensive communication and expansion possibilities that the device offers and the complete data package like set day values, monthly values, average values, maximum values of flow, power, temperature and tariff functions. The Superstatic 449 also offers communication modules of M-Bus, Radio, RS-232, GSM and LON.<br />
The Superstatic 449 &#8217;static&#8217; flow meter is EN1434 Class 2 Approved and is therefore compliant to the new Department of Energy &amp; Climate Change RHI (Renewable Heat Incentive) scheme.<br />
Please call 01773 534555 to discuss your application</p>
<p>•	Superstatic 449 240v 24Vav,12-24Vdc or Battery Powered<br />
•	Various Output Options Including ‘Volt Free’ Pulse Output (mains powered only)<br />
•	Modules avaialble: M-bus, Bi-Directional Radio, Analogue, LON (plug &amp; play)<br />
•	Cooling Options Available &#8211; Glycol Compatible (Programming available q1 2012)<br />
•	SuperStatic Meter – with no moving parts<br />
•	Sizes DN15 &amp; DN20 90C Rated<br />
•	Fully EN1434 Class 2 &amp; MID Approved<br />
•	Department of Energy &amp; Climate Change RHI (Renewable Heat Incentive) scheme compliant<br />
**PLEASE CALL 01773 534555 TO DISCUSS YOUR APPLICATION**</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2011/04/new-superstatic-449-compact-heat-meter-from-sontex/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DMS Limited available now on Facebook &amp; Twitter</title>
		<link>http://www.dmsltd.com/blog/2011/02/dms-limited-available-now-on-facebook-twitter/</link>
		<comments>http://www.dmsltd.com/blog/2011/02/dms-limited-available-now-on-facebook-twitter/#comments</comments>
		<pubDate>Tue, 15 Feb 2011 12:58:55 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Latest News]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=664</guid>
		<description><![CDATA[In addition to our website blog you can now keep up to date with the latest developments on Facebook.com and twitter.com. Over the coming months we will be releasing details of product price reductions, new products and other interesting information for our customers.

Find our Facebook page at DMS Limited Facebook Page
Or follow us on Twitter
]]></description>
			<content:encoded><![CDATA[<p>In addition to our website blog you can now keep up to date with the latest developments on Facebook.com and twitter.com. Over the coming months we will be releasing details of product price reductions, new products and other interesting information for our customers.</p>
<p><span id="more-664"></span></p>
<p><span style="margin-left: 15px;"><a href="http://www.facebook.com/?ref=hp#!/pages/DMS-Flow-Measurement-Control/189831234383531?sk=wall"><img class="alignleft size-thumbnail wp-image-675" title="facebook dms" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/02/facebook-dms-150x150.png" alt="" width="72" height="72" /></a>Find our Facebook page at <a href="http://www.facebook.com/?ref=hp#!/pages/DMS-Flow-Measurement-Control/189831234383531?sk=wall">DMS Limited Facebook Page</a></span></p>
<p><a href="http://twitter.com/#!/dmsltd2011"><img class="alignleft size-thumbnail wp-image-676" title="twitter dms" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/02/twitter-dms-150x150.jpg" alt="" width="79" height="79" /></a><span style="margin-left: 15px;">Or follow us on <a title="Follow DMS Limited on Twitter" href="http://twitter.com/#!/dmsltd2011">Twitter</a></span><a title="Follow DMS Limited on Twitter" href="http://twitter.com/#!/dmsltd2011"></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2011/02/dms-limited-available-now-on-facebook-twitter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>GWFCoder Technology and Applications</title>
		<link>http://www.dmsltd.com/blog/2010/12/gwfcoder-technology-and-applications/</link>
		<comments>http://www.dmsltd.com/blog/2010/12/gwfcoder-technology-and-applications/#comments</comments>
		<pubDate>Wed, 15 Dec 2010 09:00:33 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Gas Meters]]></category>
		<category><![CDATA[Water Meters]]></category>
		<category><![CDATA[bluetooth meter reading]]></category>
		<category><![CDATA[M-bus]]></category>
		<category><![CDATA[mobile meter reading]]></category>
		<category><![CDATA[remote meter reading]]></category>
		<category><![CDATA[wireless meter reading]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=637</guid>
		<description><![CDATA[
GWFcoder® technology:
Transfers the effective meter reading. The readout value in the billing system and the invoice are the same as the meter reading.
Pulse transfer:
The potential sources of error for a reproduced meter reading with pulse transmission are:

Bouncing
Backflow water
Temporary signal interruption
Double pulses
Incorrect pulse value

The readout value in the billing system and the invoice may differ from [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/coder-comparison.jpg"><img class="size-full wp-image-639 alignright" title="coder-comparison" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/coder-comparison.jpg" alt="Comparison of GWFCoder and pulse coding" width="535" height="265" /></a><span id="more-637"></span></p>
<h3>GWFcoder® technology:</h3>
<p>Transfers the effective meter reading. The readout value in the billing system and the invoice are the same as the meter reading.</p>
<h3>Pulse transfer:</h3>
<p>The potential sources of error for a reproduced meter reading with pulse transmission are:</p>
<ul>
<li>Bouncing</li>
<li>Backflow water</li>
<li>Temporary signal interruption</li>
<li>Double pulses</li>
<li>Incorrect pulse value</li>
</ul>
<p>The readout value in the billing system and the invoice may differ from the meter reading.</p>
<h2>GWFCoder Applications</h2>
<h3><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/wireless-pit-readout.jpg"><img class="size-full wp-image-648 alignright" title="wireless-pit-readout" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/wireless-pit-readout.jpg" alt="Wireless pit readout" width="537" height="315" /></a>Wireless pit readout</h3>
<p>Meter with GWFcoder® register, IEC interface and GWF radio module (type RCM-PI) is read out by radio using a mobile infrastructure.</p>
<h3 style="margin-top: 265px;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/gwf-read-mobile.jpg"><img class="alignright size-full wp-image-654" title="gwf-read-mobile" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/gwf-read-mobile.jpg" alt="GWF Read Mobile" width="537" height="317" /></a>GWFRead Mobile &#8211; Wall pad reading</h3>
<p>Encoder meters with a wall pad can be read without entering the property by means of an inductive wall pad. The meter data is then automatically assigned to the customer. The meter readout device then transmits this data wireless via Bluetooth to the Mobile readout<br />
device.</p>
<h3 style="margin-top: 160px;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/mbus-remote-reading.jpg"><img class="alignright size-full wp-image-659" title="mbus-remote-reading" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/mbus-remote-reading.jpg" alt="MBus Remote Reading" width="537" height="315" /></a>M-Bus remote reading</h3>
<p>The meters with GWFcoder® registers and <strong>M-Bus </strong>interfaces are connected to an <strong>M-Bus</strong> remote reading system. This ensures that the meter data is transferred directly via an <strong>M-Bus</strong> data centre or level converter to a PC where the data is further processed.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/12/gwfcoder-technology-and-applications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>GWFCoder meter reading technologies</title>
		<link>http://www.dmsltd.com/blog/2010/12/gwfcoder-meter-reading-technologies/</link>
		<comments>http://www.dmsltd.com/blog/2010/12/gwfcoder-meter-reading-technologies/#comments</comments>
		<pubDate>Wed, 08 Dec 2010 15:58:33 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Gas Meters]]></category>
		<category><![CDATA[M-bus Metering]]></category>
		<category><![CDATA[Water Meters]]></category>
		<category><![CDATA[GWFCoder]]></category>
		<category><![CDATA[mbus metering]]></category>
		<category><![CDATA[mobile meter reading]]></category>
		<category><![CDATA[opto-electronic metering]]></category>
		<category><![CDATA[remote meter reading]]></category>
		<category><![CDATA[remote metering]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=581</guid>
		<description><![CDATA[Water and gas meters with GWFCoder® register are ideal for future upgrading to remote, mobile or direct readout technologies. Examples of the various options are provided below:

Mobile on-site reading
■ Direct or outside wall readout via the inductive interface; transmission distance of up to max. 150m
■ Outside wall readout via the CL interface without access to [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Water and gas metering solutions" href="http://www.dmsltd.com/GWF_MessSysteme_AG">Water and gas meters with GWFCoder</a>® register are ideal for future upgrading to remote, mobile or direct readout technologies. Examples of the various options are provided below:<span id="more-581"></span></p>
<h3><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-mobile-onsite-reding1.jpg"><img class="size-full wp-image-585  alignright" title="dms-mobile-onsite-reding" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-mobile-onsite-reding1.jpg" alt="Mobile onsite meter reading using GWFCoder technology" width="554" height="332" /></a></h3>
<h3>Mobile on-site reading</h3>
<p>■ Direct or outside wall readout via the inductive interface; transmission distance of up to max. 150m</p>
<p>■ Outside wall readout via the CL interface without access to the measuring point; transmission distance of up to max. 150m</p>
<p>■ Mobile «walk-by» meter reading or «driveby » meter reading from a moving vehicle without access to the property</p>
<h3 style="margin-top: 160px;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-remote-meter-reading.jpg"><img class="alignright size-full wp-image-605" title="dms-remote-meter-reading" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-remote-meter-reading.jpg" alt="remote meter readining using GWFCoder technology" width="554" height="334" /></a>Remote meter reading</h3>
<p>■ The GWFcoder® technology enables the combined remote reading of water, gas and electricity meters</p>
<p>■ Depending on the interface at the communication unit (e.g. modem), various interfaces (interface converter) are available to integrate the GWFcoder® water and gas meters in the remote meter reading and to read out the meters with addresses according to IEC standards</p>
<h3 style="margin-top: 140px;">GWFCoder Variants</h3>
<p>The metering application dictates which unit is the most suitable for any installation. Suitable units are shown below for domestic and bulk, gas and water metering applications.</p>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-encoder-variants.jpg"><img class="alignnone size-large wp-image-613" title="dms-encoder-variants" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-encoder-variants-1024x411.jpg" alt="GWFCoder Variants" width="737" height="296" /></a></p>
<h3>GWF Coder Technology</h3>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-gwfcoder-how-it-works.jpg"><img class="alignleft size-full wp-image-623" title="dms-gwfcoder-how-it-works" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/12/dms-gwfcoder-how-it-works.jpg" alt="How the GWFCoder works" width="302" height="286" /></a>In the GWFcoder® system, the individual rollers of the mechanical register are read out optoelectronically. The position of the various long asymmetrically arranged slits in the roller counters is scanned using 5 light barriers (light-pipe transmitter and receiver).</p>
<p>The light barriers are implemented with phototransistors. LEDs, and light conductors, which are all consecutively scanned and evaluated. The precisely defined position of each individual roller counter is encoded as an absolute roller counter reading and read out as a part of the protocol via the GWFcoder® interface.</p>
<p>This functioning principle is patented by GWF. The GWFcoder® interface, compared to a meter with a pulse output, has an incomparably higher level of information content and readout accuracy. A GWFcoder® register does not require a battery, which, in turn, does not compromise existing revision cycles. The readout device supplies the power for the readout.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/12/gwfcoder-meter-reading-technologies/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DMS Announce Elster Jeavons Gas Regulator Stockholding &#8211; Medium Pressure</title>
		<link>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-medium-pressure/</link>
		<comments>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-medium-pressure/#comments</comments>
		<pubDate>Mon, 25 Oct 2010 08:00:53 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Jeavons Gas Regulator]]></category>
		<category><![CDATA[Latest News]]></category>
		<category><![CDATA[Elster Jeavons]]></category>
		<category><![CDATA[Gas Governors]]></category>
		<category><![CDATA[Gas Regulators]]></category>
		<category><![CDATA[industrial gas regulator]]></category>
		<category><![CDATA[Safety Valves]]></category>
		<category><![CDATA[slam shut valves]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=515</guid>
		<description><![CDATA[From the 1st January 2011 DMS will be offering ex stock delivery of the range of Elster Jeavons Medium Pressure Gas Regulators and Safety Valves.

Elster Jeavons are widely accepted as the industry standard for Low and Medium Pressure Gas Regulators and Safety Valves, DMS will be offering ex stock delivery on the wide range of [...]]]></description>
			<content:encoded><![CDATA[<p>From the 1st January 2011 DMS will be offering ex stock delivery of the range of Elster Jeavons Medium Pressure Gas Regulators and Safety Valves.</p>
<p><span id="more-515"></span></p>
<p>Elster Jeavons are widely accepted as the industry standard for Low and Medium Pressure Gas Regulators and Safety Valves, DMS will be offering ex stock delivery on the wide range of Elster Jeavons products backed up by sizing and technical advice.</p>
<p>The range of Elster Jeavons Medium Pressure Gas Regulators and Safety Valves which DMS will be holding is as follows: -</p>
<table border="0" cellspacing="0" cellpadding="0" width="100%">
<tbody>
<tr>
<td width="200px"><a title="J125 Medium Pressure Gas Regulator" href="http://www.dmsltd.com/J125_Medium_pressure_service_regulator"><img src="/images/J125-medium-pressure-gas-regulator.jpg" alt="J125 medium pressure gas regulator" /></a></td>
<td>
<h3>J125 Medium Pressure Gas Regulators with &#8216;Slam Shut&#8217; Options</h3>
<p>The <a title="Elster Jeavons J125 Medium Pressure Gas Regulator" href="http://www.dmsltd.com/J125_Medium_pressure_service_regulator">J125 Medium pressure service regulator</a>, available with (over pressure) OPSS (Under Pressure) UPSS and relief valve. Inlet pressure up to 8.6bar</p>
<p>The J125 range of regulators for service applications where accurate pressure control is required. Ideal for industrial pressure reducing, metering stations and for district distribution. Inlet pressure range of 70mb &#8211; 8.6 bar. The ¾”, 1&#8243; and 1½” sizes are available with screwed connections; the 2” size is available with screwed or flanged connections.</td>
</tr>
<tr>
<td width="200px"><a title="Elster Jeavons J123 Medium Pressure Gas Regulator " href="http://www.dmsltd.com/J123_Medium_pressure_regulator/J123_Medium_pressure_regulator"><img src="/images/J123-medium-pressure-gas-regulator.jpg" alt="J123 medium pressure gas regulator" /></a></td>
<td>
<h3>J123 Medium Pressure Gas Regulator</h3>
<p>The <a title="Elster Jeavons J123 gas regulator" href="http://www.dmsltd.com/J123_Medium_pressure_regulator/J123_Medium_pressure_regulator">J123 is a Medium pressure regulator</a> for distribution, commercial and industrial use. Inlet pressure up to 4 bar Sizes: 2&#8243;, 3&#8243; and 4”</p>
<p>The J123 is a spring loaded distribution and industrial regulator that can also be operated by auxiliary systems and is suitable for use as a monitor or active regulator. It is designed for use in installations complying with the requirements of BGC/PS/E26 (formerly DIR6) and IGE/TD/10.</td>
</tr>
</tbody>
</table>
<h2>Safety Valves</h2>
<table border="0" cellspacing="0" cellpadding="0" width="100%">
<tbody>
<tr>
<td width="200px"><a title="Elster Jeavons J120 gas governors" href="http://www.dmsltd.com/J120_Low_Pressure_Cutoff_Valve/J120_Low_Pressure_Cutoff_Valve"><img src="/images/J120-gas-governor.jpg" alt="J120 Gas Governor" /></a></td>
<td>
<h3>J120 Gas Governors (up to 2 inch size)</h3>
<p>Low pressure cut off valve, 3/4&#8221; and 1&#8221;. Auto or manual reset.</p>
<p>The<a title="Elster Jeavons J120 gas governor" href="http://www.dmsltd.com/J120_Low_Pressure_Cutoff_Valve/J120_Low_Pressure_Cutoff_Valve"> J120 is a safety valve</a> which ensures the integrity of an installation in the event of loss of gas pressure. In the event of pressure drop, the J120 is activated and shuts off the gas supply to the downstream appliances until the manual or automatic reset mechanism is operated. The J120 is available in sizes from ¾&#8221; to 2&#8243; and supplied factory set.</td>
</tr>
<tr>
<td width="200px"><a title="Elster Jeavons S100 slam shut valve" href="http://www.dmsltd.com/S100_Safety_device_DN50_DN80_DN100/S100_Safety_device_DN50_DN80_DN100"><img src="/images/J48-slam-shut-valve.jpg" alt="J48 slam shut valve" /></a></td>
<td>
<h3>J48 Slam Shut Valve (2 up to 6 inch size)</h3>
<p>Over pressure slam shut valve. 2&#8221;, 3&#8221; and 4&#8221; sizes</p>
<p>The <a title="Elster Jeavons S100 Slam Shut Valve" href="http://www.dmsltd.com/S100_Safety_device_DN50_DN80_DN100/S100_Safety_device_DN50_DN80_DN100">S100 Slam Shut Valve</a> protects gas installations against dangerous overpressure conditions and is normally fitted on the inlet side of the regulator.<br />
The S100 incorporates a visual valve position indicator. It can be supplied with a micro switch for remote indication. The manual reset has an automatic integral equalising valve ensuring safe resetting procedures and eliminating costly by-pass systems.  The S100 can be mounted in any orientation. The unit can be specified with the reset mechanism on either side of the body.</td>
</tr>
</tbody>
</table>
<h2 style="text-align: center;">Any installation of the above products <span style="text-decoration: underline;">must be</span> carried out by an approved Gas Safe Engineer</h2>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-medium-pressure/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DMS Announce Elster Jeavons Gas Regulator Stockholding &#8211; Low Pressure</title>
		<link>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-low-pressure/</link>
		<comments>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-low-pressure/#comments</comments>
		<pubDate>Mon, 25 Oct 2010 08:00:30 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Jeavons Gas Regulator]]></category>
		<category><![CDATA[Latest News]]></category>
		<category><![CDATA[appliance regulators]]></category>
		<category><![CDATA[Elster Jeavons]]></category>
		<category><![CDATA[European Gas Directive]]></category>
		<category><![CDATA[Gas Governors]]></category>
		<category><![CDATA[Gas Regulators]]></category>
		<category><![CDATA[industrial gas regulator]]></category>
		<category><![CDATA[Safety Valves]]></category>
		<category><![CDATA[slam shut valves]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=539</guid>
		<description><![CDATA[DMS now offer the range of Elster Jeavons Gas Regulators widely accepted as the industry standard for Gas Regulators and Safety Valves

The range of Elster Jeavons Gas Regulators which DMS will be holdiing is as follows: -





60DJ &#8211; 80DJ &#8211; 150DJ Gas Governors
The Elster Jeavons APPLIANCE Regulators are compact and economical. They are suitable a [...]]]></description>
			<content:encoded><![CDATA[<p>DMS now offer the range of Elster Jeavons Gas Regulators widely accepted as the industry standard for Gas Regulators and Safety Valves</p>
<p><span id="more-539"></span></p>
<p>The range of Elster Jeavons Gas Regulators which DMS will be holdiing is as follows: -</p>
<table border="0" cellspacing="0" cellpadding="0" width="100%">
<tbody>
<tr>
<td width="200px"><a title="Elster Jeavons low pressure gas governors" href="http://www.dmsltd.com/60DJ,_80DJ_~_150DJ/60DJ_-_80DJ_-_150DJ"><img src="/images/60DJ-80DJ-150DJ-gas-governors.jpg" alt="60DJ 80DJ 150DJ gas governors" /></a></td>
<td>
<h3><a href="http://www.dmsltd.com/60DJ,_80DJ_~_150DJ/60DJ_-_80DJ_-_150DJ">60DJ &#8211; 80DJ &#8211; 150DJ Gas Governors</a></h3>
<p>The Elster Jeavons APPLIANCE Regulators are compact and economical. They are suitable a wide range of domestic appliance and pilot applications with inlet pressures up to 100mbar (40&#8243;wg). They comply with the Essential Requirements of the European Gas Appliance Directive (90/396/EEC).</td>
</tr>
<tr>
<td width="200px"><a title="Elster Jeavons low pressure gas governors" href="http://www.dmsltd.com/J78/J78_Gas_Pressure_Regulator"><img src="/images/J78-and-J78R-gas-governors.jpg" alt="J78 and J78R gas governors" /></a></td>
<td>
<h3><a title="Elster Jeavons gas governors" href="http://www.dmsltd.com/J78/J78_Gas_Pressure_Regulator">J78 and J78R Gas Governors</a></h3>
<p>The J78 range is suitable for inlet pressures up to 350mbar (5psig). It meets the essential requirements of the European Gas Directive (90/396/EEC). All units are designed for natural, liquefied petroleum and manufactured gases and can be installed in horizontal or vertical pipelines.</td>
</tr>
<tr>
<td width="200px"><a title="Elster Jeavons J48 gas governors" href="http://www.dmsltd.com/J48_%28up_to_2_inch_size%29/J48_%28up_to_2_inch_size%29"><img src="/images/J48-gas-governor.jpg" alt="J48 gas governor" /></a></td>
<td>
<h3><a title="Elster Jeavons J48 gas governors" href="http://www.dmsltd.com/J48_%28up_to_2_inch_size%29/J48_%28up_to_2_inch_size%29">J48 Gas Governors</a> (up to 2 inch size)</h3>
<p>The J48 is an industrial low pressure regulator suitable for a wide range of pressure reduction applications, including such OEM equipment as boiler and burner trains for a variety of gases.</td>
</tr>
<tr>
<td width="200px"><a title="J48 gas governors" href="http://www.dmsltd.com/J48_%282_up_to_6_inch_size%29/J48_%282_up_to_6_inch_size%29"><img src="/images/J48-gas-governors-2-to-6-inch .jpg" alt="J48 gas governor 2 to 6 inch" /></a></td>
<td>
<h3><a title="Elster Jeavons J48 gas governor" href="http://www.dmsltd.com/J48_%282_up_to_6_inch_size%29/J48_%282_up_to_6_inch_size%29">J48 Gas Governors</a> (2 inch up to 6 inch size)</h3>
<p>Outlet pressures from 2&#8243; W.C. up to 64&#8243; W.C. Operating temperature range is -4°F to +158°F (-20°C to + 70°C) with a maximum allowable pressure of 5 PSIG (350 mbar). Flow rates up to 28040 SCFH (800 SCMH).</td>
</tr>
</tbody>
</table>
<h2>Any installation of the above products <span style="text-decoration: underline;">must be</span> carried out by an approved Gas Safe Engineer</h2>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/10/dms-announce-elster-jeavons-gas-regulator-stockholding-low-pressure/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Elster Jeavons Gas Regulators</title>
		<link>http://www.dmsltd.com/blog/2010/10/elster-jeavons-gas-regulators/</link>
		<comments>http://www.dmsltd.com/blog/2010/10/elster-jeavons-gas-regulators/#comments</comments>
		<pubDate>Mon, 18 Oct 2010 09:00:39 +0000</pubDate>
		<dc:creator>chrisbishop</dc:creator>
				<category><![CDATA[Gas Meters]]></category>
		<category><![CDATA[Jeavons Gas Regulator]]></category>
		<category><![CDATA[Latest News]]></category>
		<category><![CDATA[elster regulators]]></category>
		<category><![CDATA[European Regulation]]></category>
		<category><![CDATA[gas regulator]]></category>
		<category><![CDATA[jeavons gas regulators]]></category>
		<category><![CDATA[low pressure regulator]]></category>
		<category><![CDATA[medium pressure regulator]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=503</guid>
		<description><![CDATA[DMS now offer the range of Elster Jeavons Gas Regulators widely accepted as the industry standard for Gas Regulators and Safety Valves

DMS will be holding comprehensive stocks from November 1st 2010 of the Elster Jeavons Gas Governors and in January 2011 they will also have comprehensive stocks of the Elster Jeavons J125 medium pressure Gas [...]]]></description>
			<content:encoded><![CDATA[<p>DMS now offer the range of Elster Jeavons Gas Regulators widely accepted as the industry standard for Gas Regulators and Safety Valves</p>
<p><span id="more-503"></span></p>
<p>DMS will be holding comprehensive stocks from November 1st 2010 of the Elster Jeavons Gas Governors and in January 2011 they will also have comprehensive stocks of the Elster Jeavons J125 medium pressure Gas Regulators and Safety Valves.</p>
<p>The above Elster Jeavons Gas Governor stock holding will also be complimented by the addition of the S100 &#8216;Slam Shut&#8217; valve range.</p>
<p>The DMS staff will also be undergoing intensive training on the Elster Jeavons range of products to be able to give sizing and technical advice to our customers.</p>
<p style="text-align: center;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/Regulator-group.jpg"><img class="alignnone size-medium wp-image-505" title="Regulator group" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/Regulator-group-300x200.jpg" alt="" width="300" height="200" /></a></p>
<p style="text-align: center;">Any installation of the above products <strong>must be </strong>carried out by an approved Gas Safe Engineer</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/10/elster-jeavons-gas-regulators/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Elster QA Turbine Gas Meters</title>
		<link>http://www.dmsltd.com/blog/2010/10/elster-qa-turbine-gas-meters-2/</link>
		<comments>http://www.dmsltd.com/blog/2010/10/elster-qa-turbine-gas-meters-2/#comments</comments>
		<pubDate>Mon, 11 Oct 2010 09:00:15 +0000</pubDate>
		<dc:creator>chrisbishop</dc:creator>
				<category><![CDATA[Gas Meters]]></category>
		<category><![CDATA[Latest News]]></category>
		<category><![CDATA[Utility Metering Regulation]]></category>
		<category><![CDATA[gas regulator]]></category>
		<category><![CDATA[Gas Systems]]></category>
		<category><![CDATA[jeavons gas regulators]]></category>
		<category><![CDATA[low pressure regulator]]></category>
		<category><![CDATA[medium pressure regulator]]></category>
		<category><![CDATA[QA & QAe Turbine Gas Meters]]></category>
		<category><![CDATA[regulators]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=497</guid>
		<description><![CDATA[Elster QA Turbine Meters

DMS now offer the range of Elster QA Turbine Meters; they hold comprehensive stocks of Elster QA Turbine meter from 1&#8243; to 6&#8243; (DN25 to DN150)
QA Turbine Meter Specification
The wafer type housing of QA and QAe (with electronic totaliser) is made of aluminium. Depending on the version, the volume is displayed on [...]]]></description>
			<content:encoded><![CDATA[<p><strong><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/QA_QAe-Family.jpg"></a>Elster QA Turbine Meters</strong></p>
<p><span id="more-497"></span></p>
<p>DMS now offer the range of Elster QA Turbine Meters; they hold comprehensive stocks of Elster QA Turbine meter from 1&#8243; to 6&#8243; (DN25 to DN150)</p>
<p><strong>QA Turbine Meter Specification</strong></p>
<p>The wafer type housing of QA and QAe (with electronic totaliser) is made of aluminium. Depending on the version, the volume is displayed on a mechanical (QA) or an electronic totaliser (QAe). QA and QAe Quantometers combine the high accuracy of the Q series of Quantometers with low weight.<br />
The Quantometers are available in a number of flow ranges, diameters and pressure ratings. Depending on the version, a low or medium-frequency pulse transmitter and an optical readout or an optical readout with additional M-bus output is available.</p>
<p>All of the Quantometers are DVGW approved.<a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/QA_QAe-Family.jpg"></a><br />
For special industrial applications, stainless steel versions are also available.</p>
<p style="text-align: center;"><strong>QA Turbine Meter Family</strong></p>
<p style="text-align: center;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/QA_QAe-Family.jpg"><img class="alignnone size-medium wp-image-500" title="QA_QAe Family" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/QA_QAe-Family-300x233.jpg" alt="" width="300" height="233" /></a> </p>
<p style="text-align: center;">Any installation of the above products <strong>must be </strong>carried out by an approved Gas Safe Engineer</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/10/elster-qa-turbine-gas-meters-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>