<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DMS Ltd &#187; Cooling Meters</title>
	<atom:link href="http://www.dmsltd.com/blog/category/cooling-meters/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.dmsltd.com/blog</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Fri, 12 Aug 2011 09:55:01 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Renewable Heat Incentive (RHI) Scheme</title>
		<link>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/</link>
		<comments>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/#comments</comments>
		<pubDate>Tue, 31 May 2011 09:00:36 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Cooling Meters]]></category>
		<category><![CDATA[Glycol Meters]]></category>
		<category><![CDATA[Sontex Heat Meters]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=707</guid>
		<description><![CDATA[The Government will allow those who wish to make a claim against the Renewable Heat Incentive Scheme to choose any heat meter that meets the Class 2 requirements listed in Annex MI-004 of the EU Measuring Instruments Directive (MID) 2004.
The following Heat Meters supplied by DMS, comply to these requirements.

 

The Sontex Superstatic 440 is [...]]]></description>
			<content:encoded><![CDATA[<p>The Government will allow those who wish to make a claim against the <a title="Renewable Heat Incentive Scheme" href="http://www.decc.gov.uk/en/content/cms/what_we_do/uk_supply/energy_mix/renewable/policy/incentive/incentive.aspx " target="_blank">Renewable Heat Incentive Scheme</a> to choose any heat meter that meets the Class 2 requirements listed in <em>Annex </em>MI-004 of the EU Measuring Instruments Directive (MID) 2004.<span id="more-707"></span></p>
<p style="text-align: center;"><strong>The following Heat Meters supplied by DMS, comply to these requirements.<br />
</strong></p>
<p><strong> </strong></p>
<p><strong><a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms-blog1.jpg"><img class="alignleft size-full wp-image-709" title="dms blog" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms-blog1.jpg" alt="" width="176" height="150" /></a></strong><br />
The Sontex <strong>Superstatic 440</strong> is a &#8217;static&#8217; meter with no moving parts<br />
using the fluid oscillation principle</p>
<p><strong>Supercal 531</strong> Power Options: 240Vac, 24Vac, 24VDC, Lithium Battery</p>
<p>Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p>Sizes Available: 1/2&#8243; (qp1.00) to DN500 (qp1500)</p>
<p>Suitable for: Heating &amp; Cooling with Glycol content</p>
<p>Communication Modules: Pulse (volt free,) M-bus, RS232, Analogue, Radio</p>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms.jpg"><img class="size-full wp-image-711 alignleft" title="dms" src="http://www.dmsltd.com/blog/wp-content/uploads/2011/05/dms.jpg" alt="" width="170" height="136" /></a><br />
The Sontex <strong>Superstatic 449</strong> is a &#8217;static&#8217; Compact Meter with no moving parts<br />
using the fluid oscillation principle</p>
<p>Supercal 531 Power Options: 240Vac, 24Vac, 24VDC, Lithium Battery</p>
<p>Approvals: EN1434 Class 2 &amp; MID RHI Compliant</p>
<p>Sizes Available: 1/2&#8243; (qp1.0) to 3/4&#8243; (qp2.5)</p>
<p style="text-align: left;">Suitable for: Heating &amp; Cooling with Glycol content (released 2012)</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2011/05/renewable-heat-incentive-rhi-scheme/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Got a Problem Metering Energy in Systems with Glycol Content</title>
		<link>http://www.dmsltd.com/blog/2010/10/got-a-problem-metering-energy-in-systems-with-glycol-content-2/</link>
		<comments>http://www.dmsltd.com/blog/2010/10/got-a-problem-metering-energy-in-systems-with-glycol-content-2/#comments</comments>
		<pubDate>Wed, 06 Oct 2010 10:58:43 +0000</pubDate>
		<dc:creator>Rob</dc:creator>
				<category><![CDATA[Cooling Meters]]></category>
		<category><![CDATA[Glycol Meters]]></category>
		<category><![CDATA[M-bus Metering]]></category>
		<category><![CDATA[Sontex Heat Meters]]></category>
		<category><![CDATA[EN1431 approved]]></category>
		<category><![CDATA[M-bus]]></category>
		<category><![CDATA[MID Approved]]></category>
		<category><![CDATA[Smart Integrator]]></category>
		<category><![CDATA[Sontex Supercal 531]]></category>
		<category><![CDATA[Superstatic 440 flow meter]]></category>
		<category><![CDATA[SuperStatic 440 Meter]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=476</guid>
		<description><![CDATA[Meet the Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter
The Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter with no moving parts is your answer to systems containing glycol. The Supercal 531 can be programmed for the type of glycol and the concentration percentage to give you [...]]]></description>
			<content:encoded><![CDATA[<h3>Meet the Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter</h3>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/sontex_supercal_531_and_superstatic_440.jpg"><img class="alignright size-full wp-image-479" title="sontex supercal 531 and superstatic 440 flow meter" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/10/sontex_supercal_531_and_superstatic_440.jpg" alt="sontex supercal 531 and superstatic 440 flow meter" width="300" height="268" /></a>The Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter with no moving parts is your answer to systems containing glycol. The Supercal 531 can be programmed for the type of glycol and the concentration percentage to give you accurate readings where some heat meters will not operate at all.<span id="more-476"></span></p>
<h3>Sontex flow measurement metering systems</h3>
<p>With a range of outputs available the Supercal/Superstatic combination can be tailored for your needs for either heating or cooling applications at competitive prices.</p>
<ul>
<li>Supercal 531 Smart Integrator 240v or Battery Powered</li>
<li>Various Output Options Including ‘Volt Free’ Pulse Output</li>
<li>M-bus, Bi-Directional Radio, Analogue, LON (Gateway)</li>
<li>60+ Glycol Programmes (more added monthly)</li>
<li>Temperature Range -20C to 200C</li>
<li>SuperStatic 440 Meter – with no moving parts</li>
<li>-20C to 130C Rated (Flanged Versions)</li>
<li>Sizes DN15 to DN500</li>
</ul>
<p>Fully EN1431 &amp; MID Approved</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/10/got-a-problem-metering-energy-in-systems-with-glycol-content-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Glycol Cooling &amp; Heat Meters &#8211; Sontex Supercal 531 / Superstaic 440</title>
		<link>http://www.dmsltd.com/blog/2010/04/glycol-cooling-heat-meters-sontex-supercal-531-superstaic-440/</link>
		<comments>http://www.dmsltd.com/blog/2010/04/glycol-cooling-heat-meters-sontex-supercal-531-superstaic-440/#comments</comments>
		<pubDate>Wed, 21 Apr 2010 12:36:31 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Cooling Meters]]></category>
		<category><![CDATA[Glycol Meters]]></category>
		<category><![CDATA[Sontex Heat Meters]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[energy meter]]></category>
		<category><![CDATA[glycol]]></category>
		<category><![CDATA[glycol heat meter]]></category>
		<category><![CDATA[heat]]></category>
		<category><![CDATA[Heat Meter]]></category>
		<category><![CDATA[Heat Meter Data Collection]]></category>
		<category><![CDATA[Heat Meters]]></category>
		<category><![CDATA[solar thermal heat meter]]></category>
		<category><![CDATA[solar thermal meter]]></category>
		<category><![CDATA[thermal heat meter]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=291</guid>
		<description><![CDATA[Got a Problem Metering Energy in Systems with Glycol Content &#8211; Not a Problem now!!


The Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter with no moving parts is your answer to systems containing glycol. The Supercal 531 can be programmed for the type of glycol and the concentration percentage to give [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Got a Problem Metering Energy in Systems with Glycol Content &#8211; Not a Problem now!!</strong></p>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/04/Sontex-Logo.jpg"><img class="alignnone size-full wp-image-293" title="Sontex Logo" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/04/Sontex-Logo.jpg" alt="" width="345" height="81" /></a><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/04/Sontex-Logo.jpg"></a></p>
<p><span id="more-291"></span></p>
<p>The Sontex Supercal 531 Smart Integrator and the Superstatic 440 &#8217;static&#8217; flow meter with no moving parts is your answer to systems containing glycol. The Supercal 531 can be programmed for the type of glycol and the concentration percentage to give you accurate readings where some heat meters will not operate at all.</p>
<p>With the range of outputs available the Supercal/Superstatic combination can be tailored for your needs for either heating or cooling applications at competitive prices.</p>
<p style="text-align: center;"><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/04/Sontex-440.jpg"><img class="size-full wp-image-294  aligncenter" title="Sontex 440" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/04/Sontex-440.jpg" alt="" width="154" height="154" /></a></p>
<p>Please call 01773 534555 to discuss your application</p>
<p><a href="http://www.dmsltd.com/SONTEX/Supercal_531_The_New_Multi-Functional_Integrator" target="_blank"><strong>Sontex Superstatic 440 / Supercal 531 - Please Click Here</strong></a></p>
<ul>
<li>Supercal 531 Smart Integrator 240v or Battery Powered</li>
<li>Various Output Options Including ‘Volt Free’ Pulse Output</li>
<li>M-bus, Bi-Directional Radio, Analogue, LON (Gateway)</li>
<li>60+ Glycol Programmes (more added monthly)</li>
<li>Temperature Range -20C to 200C</li>
<li>SuperStatic 440 Meter – with no moving parts</li>
<li>-20C to 130C Rated (Flanged Versions)</li>
<li>Sizes DN15 to DN250</li>
<li style="text-align: left;">Fully EN1431 &amp; MID Approved</li>
</ul>
<p style="text-align: center;">**PLEASE CALL 01773 534555 TO DISCUSS YOUR APPLICATION**</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/04/glycol-cooling-heat-meters-sontex-supercal-531-superstaic-440/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Got a Problem Metering Energy in Systems with Glycol Content</title>
		<link>http://www.dmsltd.com/blog/2010/02/got-a-problem-metering-energy-in-systems-with-glycol-content/</link>
		<comments>http://www.dmsltd.com/blog/2010/02/got-a-problem-metering-energy-in-systems-with-glycol-content/#comments</comments>
		<pubDate>Fri, 26 Feb 2010 12:29:17 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Cooling Meters]]></category>
		<category><![CDATA[Glycol Meters]]></category>
		<category><![CDATA[Sontex Heat Meters]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[energy meter]]></category>
		<category><![CDATA[glycol]]></category>
		<category><![CDATA[glycol heat meter]]></category>
		<category><![CDATA[Heat Meter]]></category>
		<category><![CDATA[solar thermal heat meter]]></category>
		<category><![CDATA[solar thermal meter]]></category>
		<category><![CDATA[thermal heat meter]]></category>

		<guid isPermaLink="false">http://www.dmsltd.com/blog/?p=257</guid>
		<description><![CDATA[Got a Problem Metering Energy in Systems with Glycol Content
Not a Problem now!! 


Sontex Superstatic 440 &#38; Supercal 531
Supercal 531 Smart Integrator 240v or Battery Powered
Various Output Options Including Volt Free Pulse Output
M-bus, Bi-Directional Radio, Analogue, LON (Gateway)
60+ Glycol Programmes (more added monthly)
Temperature Range -20C to 200C
SuperStatic 440 Meter with no moving parts
-20C to 130C [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Got a Problem Metering Energy in Systems with Glycol Content</strong></p>
<p><strong>Not a Problem now!! </strong></p>
<p><span id="more-257"></span></p>
<p><a href="http://www.dmsltd.com/blog/wp-content/uploads/2010/02/SC531-Superstatic3.jpg"><img class="size-full wp-image-266 alignnone" title="SC531 Superstatic" src="http://www.dmsltd.com/blog/wp-content/uploads/2010/02/SC531-Superstatic3.jpg" alt="" width="167" height="165" /></a></p>
<p><strong><span style="text-decoration: underline;"><a href="http://www.dmsltd.com/SONTEX/Supercal_531_The_New_Multi-Functional_Integrator" target="_self">Sontex Superstatic 440 &amp; Supercal 531</a></span></strong></p>
<p>Supercal 531 Smart Integrator 240v or Battery Powered<strong></strong></p>
<li>Various Output Options Including <strong>Volt Free</strong> Pulse Output</li>
<li>M-bus, Bi-Directional Radio, Analogue, LON (Gateway)</li>
<li>60+ Glycol Programmes (more added monthly)</li>
<li>Temperature Range -20C to 200C</li>
<li>SuperStatic 440 Meter with no moving parts</li>
<li>-20C to 130C Rated (Flanged Versions)</li>
<li>Sizes DN15 to DN250</li>
<li>Fully EN1431 &amp; MID Approved</li>
<p> **PLEASE CALL 01773 534555 TO DISCUSS YOUR APPLICATION**</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dmsltd.com/blog/2010/02/got-a-problem-metering-energy-in-systems-with-glycol-content/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

